To request training and access

Bolortuya  Badamdorj
Bolortuya Badamdorj
Phone:+49 331 567-9152Fax:+49 331 567-9502

Leica DMR Microscope

Description

The Leica DMR is a light microscope with various options for illumination and signal detection.

The Polarization microscopy is one of the most important research methods in science. It is used to determine the optical properties of the crystals and is used without further chemical and physical analysis processes. Since the optical properties of the crystals are closely related to their structural composition, crystallographic assignments can be derived from polarization-optical measurements. By means of special technical equipment on the measuring instrument polarizing microscope, almost all crystal-optical data can be determined, especially on microscopically small crystals.



Specification:

  • Software: Leica LasV3.8
  • High Resolution Leica Camera DFC 280
  • XY Stage Manual
  • Manual Focus Drive (coarse/fine)
  • Illumination: Transmitted and Reflective
  • Polarisation Filter for Illumination
  • Objectives:
    • PL FLUOTAR 2.5x/0.07
    • PL FLUOTAR 5x/0.12
    • PL FLUOTAR 10x/0.30-PH1
    • PL FLUOTAR 20x/0.50-PH2
    • PL FLUOTAR 40x/0.70-PH2
    • 63x/0.75
    • PL FLUOTAR 100x/1.30 OIL-PH3

Cold Field Emission Gun
Accelerating voltages: 60, 80 & 200 kV
Probe (STEM)-Cs-Corrector; Image (TEM)-Cs-Corrector
JED-2300 Energy-dispersive X-ray detector, 100mm<sup>2</sup>
Gatan GIF Quantum
Gatan OneView (4k x 4k) & Gatan US1000 (2k x 2k) cameras

Jeol JEM-ARM200F TEM

Cold Field Emission Gun Accelerating voltages: 60, 80 & 200 kV Probe (STEM)-Cs-Corrector; Image (TEM)-Cs-Corrector JED-2300 Energy-dispersive X-ray detector, 100mm2 Gatan GIF Quantum Gatan OneView (4k x 4k) & Gatan US1000 (2k x 2k) cameras [more]

LaB<sub>6</sub> cathode
Lateral resolution: 0.37 nm
Point resolution: 0.34 nm
Accelerating voltage: 120 kV
Magnifications: 80-500000x
OMEGA-type in-column energy-filter

Zeiss TEM 912 Omega

LaB6 cathode Lateral resolution: 0.37 nm Point resolution: 0.34 nm Accelerating voltage: 120 kV Magnifications: 80-500000x OMEGA-type in-column energy-filter [more]

Thermal field emission gun
Resolution at 1 kV: 3 nm
Resolution at 20 kV: 1 nm
Accelerating voltage: 0.2 to 30 kV
Magnification: 20-900000x

SEM Gemini 1550 (Zeiss AG)

Thermal field emission gun Resolution at 1 kV: 3 nm Resolution at 20 kV: 1 nm Accelerating voltage: 0.2 to 30 kV Magnification: 20-900000x [more]

Software Leica LasX
High Resolution 10-Megapixel Camera
2D and 3D Measurements
XY-Stage, Manual and Motorized
Focus Drive (coarse/fine), Manual and Motorized
Tilting Angle, Continuous Adjustment from  ± 60°
Illumination: Transmitted and Reflective

Digital Microscope Leica DVM6

Software Leica LasX High Resolution 10-Megapixel Camera 2D and 3D Measurements XY-Stage, Manual and Motorized Focus Drive (coarse/fine), Manual and Motorized Tilting Angle, Continuous Adjustment from  ± 60° Illumination: Transmitted and Reflective [more]

Software: Leica LasV3.8
High Resolution Leica Camera DFC 280
XY Stage Manual
Manual Focus Drive (coarse/fine)
Illumination: Transmitted and Reflective
Polarisation Filter for Illumination

Leica DMR Microscope

Software: Leica LasV3.8 High Resolution Leica Camera DFC 280 XY Stage Manual Manual Focus Drive (coarse/fine) Illumination: Transmitted and Reflective Polarisation Filter for Illumination [more]
 
loading content